Onan generators: what fails first, what it costs, and how to keep one ready for storm season
Onan is what is mounted in most motorhomes and a good many fifth wheels, and in Highlands County it fails in one dominant way: it sits. The use pattern here, parked on a resort site or in a storage lot from April to November with fuel in the system, through the hottest and wettest months of the year, is close to the worst thing you can do to a small gasoline engine. Most November generator failures trace back to it, and so do most “it would not start the night the power went out” stories after a storm.
The fuel problem, in detail
Modern pump gasoline is not a storage fluid. In a carburetor bowl at the temperature of a closed generator compartment in July, the volatile fractions evaporate and leave behind a sticky varnish that sets in the jets and the small passages. Those passages are measured in thousandths of an inch. Ethanol content makes it worse in a second way, and worse here than in a dry climate: it draws moisture out of 79-percent-humidity air, and that water corrodes the aluminum carburetor body from the inside.
So the engine turns over and never catches, or catches and quits, or keeps running but hunts up and down. All three are the same underlying fault and all three are fixed the same way: the carburetor comes off, gets cleaned or rebuilt, and the fuel system gets checked back to the tank.
What things cost
| Job | Range |
|---|---|
| Trip fee | $75 to $150 |
| Labor | $125 to $190/hr |
| Carburetor clean or rebuild | $350 to $800 |
| Full service: oil, filter, air filter, plugs, load test | $300 to $550 |
| Fuel pump or fuel system repair | $350 to $900 |
| No AC output: brushes, capacitor, regulator, breaker | $400 to $1,200 |
| Control board after a surge | $400 to $900 |
| Larger internal work | Quoted after diagnosis |
Same approach as everything on the pricing page: diagnose, quote, get your approval, then work.
What goes wrong first, and what goes wrong next
- Fuel system, far ahead of anything else, because of the varnish and water described above.
- Plugs and air filters, neglected because the generator is out of sight, and an air filter in this humidity holds moisture.
- Oil, which is due by hours on the meter rather than by the calendar, and on a lot of resort rigs has simply never been changed. Generator hour meters exist for a reason.
- Engine runs, but no power reaches the coach. Now we are on the electrical end: brushes, the capacitor, the voltage regulator, or the breaker on the generator tripping. At least it tells us the engine is healthy.
- Control boards and regulators after lightning. Florida leads the country in lightning density, and the generator’s control board is on the rig’s 12V system, downstream of the converter. A pedestal surge that kills the converter can reach it.
- Starting and control faults, including the remote start panel and its wiring, and mud daubers in the compartment.
- Exhaust, which is a safety item rather than a performance one and is covered below.
Storm season is why this matters here
Highlands County has lost power almost countywide twice in recent memory. Hurricane Irma in September 2017 left 90 percent of the county without power at its peak, and the county was the second-hardest-hit in Florida. Hurricane Ian on the evening of September 28, 2022 brought gusts of 66 to 72 mph across the county and a near-total outage for at least 24 hours, with most customers back by the following Sunday. Both times, the generator that had been sitting since April with old fuel in the bowl was the generator that did not start.
If you are in the rig through hurricane season, the generator is not a convenience. A full service in May or June, with fresh fuel run through it and a real load test, is the difference between a cool rig with a working fridge for three days and a very long weekend. The generator repair service page covers the full scope.
One monthly habit heads off most of this
Every month, give it two hours with a real load on it. Idling it, or a quick five-minute start, does not count. Under load, meaning with an air conditioner running, long enough to get everything hot.
A generator run this way rarely refuses to start. It keeps fresh fuel in the bowl, keeps the carburetor wet, circulates oil, dries the windings, and exercises the start circuit. It costs nothing and needs no tools, and of everything we recommend to Highlands County owners, this habit pays back the most.
If the rig genuinely has to sit through the summer, the next best options are treating the fuel with a stabilizer and running it through, or shutting off the fuel and running the bowl dry where the unit allows it.
Heat, humidity, and honest expectations
Generators are rated under standard conditions, and output falls as temperature and humidity rise. On a 92-degree, saturated Highlands County afternoon your unit is not making its nameplate number. If it has always struggled to carry two rooftop air conditioners in July, that may be physics rather than a fault, and we will not sell you a rebuild for it.
The practical fixes for that are cheap: stagger the AC starts rather than letting both compressors hit at once, and consider soft-start devices on the air conditioners, which dramatically cut inrush current. A lot of owners who swear the generator is too small for the rig end up fixed for less than any repair would cost.
The safety paragraph
Two things to raise on any generator visit:
Exhaust integrity. A leaking generator exhaust on a motorhome is a carbon monoxide risk, and these systems live in a harsh, wet environment underneath a vehicle where steel rusts fast. A leaking exhaust means not running the unit until it is repaired.
Your CO alarm. Press the test button and read the expiry date on the back, since these alarms age out. Of everything on this page, that costs nothing and matters most.
Generators get serviced on site across Sebring, Avon Park, Lake Placid, the Lorida fish camps, Frostproof, Wauchula, and Okeechobee.
Frequently Asked Questions
Why will my Onan not start after sitting all summer?
Fuel. Pump gasoline with ethanol left in a carburetor bowl through a hot, humid Florida summer evaporates its light fractions, leaves varnish in the jets, and draws moisture that corrodes the aluminum. The generator cranks and will not fire, or fires and dies, or surges. The fix is a carburetor clean or rebuild, $350 to $800.
The engine runs fine but there is no power. What is that?
The electrical side: brushes, a capacitor, the voltage regulator, or the breaker on the unit itself. It is good news in one sense, because the engine is fine. Repairs run $400 to $1,200 depending on what it is, and a surge from a nearby lightning strike is a common cause of a dead regulator or board.
Can you get my generator ready before hurricane season?
Yes, and it is the best time to call about one. A full service (oil, filters, plugs, a load test, a fuel system check) is $300 to $550. Highlands County lost power almost countywide in both Irma and Ian; the generator that has been run under load every month is the one that starts that night.
How often should I run it?
Two hours a month under load, meaning with the air conditioner running, long enough to get everything hot. Owners who do this essentially never end up with a generator that will not start. It is free and it is the most effective maintenance advice on this site.
What we do in Sebring
- Mobile RV Repair in Sebring: We Come to the Rig
- RV Roof Repair & Resealing in Sebring, Florida
- RV Air Conditioner Repair in Sebring, Florida
- RV Slide-Out Repair in Sebring, Florida
- RV Plumbing & Water Heater Repair in Sebring, Florida
- RV Appliance & 12V Electrical Repair in Sebring, Florida
- RV Fiberglass and Delamination Repair in Sebring, Florida
- RV Generator Repair in Sebring, Florida
Sebring Mobile RV Repair